Modern server rooms house critical IT infrastructure, including servers, networking equipment, and supporting power and cooling systems. Depending on operational scale, a server room may contain anywhere from a few racks to hundreds of servers, all securely organized within rack enclosures for efficiency, safety, and ease of maintenance. These servers typically operate without local displays or input devices and are monitored and managed remotely from centralized control locations.
As computing demands continue to grow, server room power requirements become increasingly complex and critical. To maintain uninterrupted operation and protect sensitive equipment from power disturbances, a reliable uninterruptible power supply (UPS) system is essential. For medium to large server room applications, a double conversion true online UPS in the 10–300 kVA range is the preferred solution, delivering continuous, clean power, zero transfer time, and maximum protection for mission-critical IT environments.
Ciri
In a true online double-conversion UPS, the inverter operates continuously to deliver clean, stable, and reliable power at all times. This design ensures complete isolation of the connected load from utility power disturbances, making it ideal for applications where uninterrupted uptime is critical.
By converting incoming AC power to DC through a rectifier and then back to AC via the inverter, the UPS provides precise voltage regulation, stable output frequency, and effective protection against surges, sags, harmonics, and electrical noise. In the event of a mains power failure, the system seamlessly draws energy from the battery without any transfer delay, ensuring uninterrupted power delivery to critical equipment.
| Model | LFL300 |
|---|---|
| Kuasa | 10–300 kVA |
| Julat Voltan Masukan | 380 VAC ±25% (boleh disesuaikan) |
| Voltan Keluaran | 380 VAC ±1% (boleh disesuaikan) |
| Konfigurasi Fasa | Input tiga fasa / Output tiga fasa |
| Bentuk Gelombang Output | Gelombang sinus tulen |
| Kekerapan Kerja | 50/60 Hz |
| Masa Perpindahan | 0 ms |
| Jenis Bateri | Bateri asid plumbum yang dimeteraikan |
| Voltan Bateri | 384 VDC (boleh laras) |
| Masa Sandaran | Boleh disesuaikan |
| Perlindungan | Perlindungan litar pintas elektronik, pengehadan arus pada arus undian 1.3× |
| Keupayaan Beban Lebih | 110% selama 10 minit; 125% selama 3 minit; 150% selama 1 minit |
| Petunjuk LED | Input, penyongsang, pintasan, status bateri |
| Paparan LCD | Voltan input/output, frekuensi, voltan bateri, peratusan beban, suhu |
| Herotan Bentuk Gelombang | ≤3% (beban linear), ≤5% (beban tak linear) |
| Suhu Kerja | 0°C hingga +45°C |
| Suhu Penyimpanan | -25°C hingga +55°C |
| Kelembapan Relatif | 0–95% (tanpa pemeluwapan) |
| Ketinggian | ≤ 1000 m |
| Tahap Bunyi | < 50 dB |
| Antara Muka Komunikasi | RS485, RS232, USB, sentuhan kering, slot kad pengembangan pintar |
| Piawaian | IEC 62040-1 |
| Penarafan IP | IP20 |





Ulasan