塔式UPS 2kva双转换UPS

Tower ups 2kva double conversion ups, we offer full customization, design customization, and sample customization services, along with product certifications. also available 1KVA 3KVA 6KVA 8KVA 10KVA online UPS

分类: 标签:

High Frequency Online UPS tower series T1K-10KVA(1ph in/1ph out) features

  • True online double-conversion UPS with pure sine-wave output for maximum power protection
  • Rugged industrial design with conformal coating, providing strong anti-corrosion performance in harsh environments
  • Extra-wide input voltage range (90–300 Vac), fully compatible with generator power
  • Built-in input power factor correction (PFC) to reduce energy loss and lower wiring costs
  • High overload and surge handling capability, ideal for laser printers, ultrasonic cleaners, and other demanding loads
  • Compact footprint to save valuable installation space
  • Customization-ready design for seamless integration with automatic control and monitoring systems
Tower Model T1K T1KL T2K T2KL T3K T3KL T6K T6KL T10K T10KL
Rack Mount Model RT1K RT1KL RT2K RT2KL RT3K RT3KL RT6K RT6KL RT10K RT10KL
阶段 1Phase 2Wire + PE
容量 1KVA / 900W 2KVA / 1.8KW 3KVA / 2.7KW 6KVA / 5.4KW 10KVA / 9KW
输入
Nominal Input Voltage 110 / 115 / 120 / 127VAC or 220 / 230 / 240VAC 220 / 230 / 240VAC
输入电压范围 110 / 115 / 120 / 127VAC: 60V~300V Halfload 176V~300V Full Load
220 / 230 / 240VAC: 90V~300V Halfload 176V~300V Full Load
110V~300V Halfload 176V~300V Full Load
Input Frequency Range 40~70Hz
输入功率因数 0.99 @Full load
输出
输出电压 230Vac (220 / 240 / 208 Selectable) or 120Vac (100 / 110 / 115 / 127V Selectable) 230V (220 / 240 / 208 Selectable)
Output Voltage Regulation 1%
Output Frequency (Sync.Mode) 46Hz ~ 54Hz / 57Hz ~ 63Hz 46Hz ~ 54Hz / 56Hz ~ 64Hz
Output Frequency (Bat.Mode) 50Hz+ / -0.05Hz 60Hz+ / -0.05Hz
Output THDv% 2% Linear Load 6% Non-Linear Load 2% Linear Load 5% Non-Linear Load
输出波形 纯正弦波
转乘时间
Line mode ↔ Bat Mode 0ms
Inv ↔ Bypass Mode <4ms
效率
AC–>AC 89% 90% 91% >93%
ECO 94% 95% 96% >95%
电池模式 87% 88% 89% >90%
Battery & Charger
Battery Voltage / Capacity 2*12V/7AH 24V/36V
External Battery
4*12V/7AH 48V/72V
External Battery
6*12V/7AH 72V/96V
External Battery
12*12V/7AH 144V/192V
External Battery
16*12V/7AH 192V/240V
External Battery
电池类型 Valve Regulated Maintenance Free Lead Acid (VRLA) for Standard Model with Internal Battery
Recharge Time ~ 5 Hours Subject to
External Battery
Config
~ 5 Hours Subject to
External Battery
Config
~ 5 Hours Subject to
External Battery
Config
~ 5 Hours Subject to
External Battery
Config
~ 5 Hours Subject to
External Battery
Config
Max Recharge Current 1.5A 6A 1.5A 6A 1.5A 6A 1.5A 4A 1.5A 4A
Floating Charge Votlage 27.3V 27.3V / 41.0V 54.6V 54.6V / 81.8V 81.8V 81.8V/109.2V 163.8V 163.8V/218.4V 218.4V 218.4V/273V
HMI
展示 LED / LCD (Option)
Buzzer Alarm Bat.Mode / Bat.Low / OverLoad / Fault
通信端口 RS232 / SNMP (Option) / USB(Option)
Physical
Form Factor Tower / Rack
Dimension(Tower) – W*H*L(mm) 145*220*328 145*220*400 145*220*328 190*318*380 190*360*540 190*340*540 190*360*680 190*340*540
Dimension (Rack) – W*H*D(mm) 438*88(2U)*350 438*88(2U)*500
Weight(KG) 8.9 6.1 17.5 10.6 21.6 10.8 37 15.4 48 16
环境
湿度 5 ~ 97% (Non Condensing)
Operating Ambient Temperature 0~40oC
*External Battery Pack Rated Voltage Can Select Upon Order, 192 / 240V
*Product Specifications are Subject to Change Without Notice.