<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UPS 30 kva, Three-Phase Online UPS Power Supply - UPS power supply</title>
	<atom:link href="https://www.upspower-supply.com/product-tag/ups-30-kva/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.upspower-supply.com/product-tag/ups-30-kva/</link>
	<description></description>
	<lastBuildDate>Tue, 28 Jul 2026 12:35:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://www.upspower-supply.com/wp-content/uploads/2025/05/cropped-ups-power-supply-icon-e1747119276228-32x32.jpg</url>
	<title>UPS 30 kva, Three-Phase Online UPS Power Supply - UPS power supply</title>
	<link>https://www.upspower-supply.com/product-tag/ups-30-kva/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>30 kva ups, Pure sine wave data center UPS</title>
		<link>https://www.upspower-supply.com/product/30-kva-ups-pure-sine-wave-data-center-ups/</link>
					<comments>https://www.upspower-supply.com/product/30-kva-ups-pure-sine-wave-data-center-ups/#respond</comments>
		
		<dc:creator><![CDATA[Tyne Tingey]]></dc:creator>
		<pubDate>Tue, 30 Dec 2025 09:15:08 +0000</pubDate>
				<guid isPermaLink="false">https://www.upspower-supply.com/?post_type=product&#038;p=2031</guid>

					<description><![CDATA[<p>3 Phase Online UPS &#124; 30KVA / 30KW &#124; OUTPUT PF 1 &#124; 3P/3P &#124; 380Vac/400Vac/415Vac &#124; Max. 6 units in parallel</p>
<p>As trusted data center UPS manufacturers, UPSPower engineers the 30 kVA true online double-conversion 3-phase UPS to maximize space efficiency while simplifying runtime scalability for growing power demands.</p>
<p><strong>Why choose UPSPower as your data center UPS manufacturer?</strong></p>
<p>With 15+ years of manufacturing experience and deployments across 120+ countries, UPSPower supplies data centers with enterprise-grade power protection built for mission-critical uptime. Every unit is tested to IEC and EN standards before leaving the factory.</p>
<p>The post <a href="https://www.upspower-supply.com/product/30-kva-ups-pure-sine-wave-data-center-ups/">30 kva ups, Pure sine wave data center UPS</a> appeared first on <a href="https://www.upspower-supply.com">UPS power supply</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>UPSPower’s true online double-conversion 3-phase 30 kVA data center UPS has been redesigned to maximize space efficiency while simplifying runtime scalability for growing power demands.</p>
<p>This 3-phase 380/400/415 V, 30 kVA / 30 kW online double-conversion UPS utilizes advanced IGBT technology to deliver reliable battery backup and continuous AC power protection. It effectively safeguards critical systems from power disturbances that can damage electronic equipment or cause data loss. The UPS is ideally suited for data centers, corporate IT infrastructure, telecom applications, LAN/WAN networks, security and emergency systems, financial institutions, and light industrial environments.</p>
<p>System management is made easy through an intuitive front-panel LCD interface, which provides real-time visibility into key operating parameters, including load level, available runtime, battery status, alarm conditions, and input/output voltage and frequency. A built-in expansion slot supports optional SNMP or AS400 cards, enabling remote monitoring, network integration, and centralized power management.</p>
<p>&nbsp;</p>
<h2>3 Phase 30 kVA UPS – Reliable Power Protection</h2>
<p>Protect your critical IT, telecom, security, and corporate systems with our 3 Phase 30 kVA UPS. True online double-conversion technology ensures stable, clean sine wave output, ±1% voltage regulation, and power factor 1 for maximum efficiency.</p>
<ul>
<li>IGBT inverter with &lt;2% THD output for safe, reliable operation</li>
<li>Wide input voltage range (190–478 V) to extend battery life</li>
<li>Modular, front-access design for easy data center maintenance</li>
<li>Supports up to 6 units in parallel for scalable data center capacity</li>
<li>Automatic and manual bypass for uninterrupted power</li>
<li>High-efficiency ECO mode up to 99%</li>
<li>SNMP/Web-ready for remote monitoring and control</li>
<li>Compact tower design with optional external battery cabinets</li>
</ul>
<p>The 3 Phase 30 kVA UPS combines high efficiency, reliability, and flexibility, making it ideal for data centers, industrial facilities, and mission-critical environments.</p>
<h4>Specification</h4>
<table class="w-full border border-gray-300 text-sm">
<tbody>
<tr class="bg-gray-100 font-semibold">
<td class="border px-4 py-2">Model</td>
<td class="border px-4 py-2">UP30K</td>
</tr>
<tr>
<td class="border px-4 py-2">Capacity</td>
<td class="border px-4 py-2">30 KVA / 30 KW</td>
</tr>
<tr>
<td class="border px-4 py-2">Noise</td>
<td class="border px-4 py-2">Less than 65 dB @ 1 Meter</td>
</tr>
<tr>
<td class="border px-4 py-2">Dimension (WxDxH mm)</td>
<td class="border px-4 py-2">815 x 300 x 1000</td>
</tr>
<tr>
<td class="border px-4 py-2">Weight (Kgs)</td>
<td class="border px-4 py-2">56</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">INPUT</td>
</tr>
<tr>
<td class="border px-4 py-2">Nominal Voltage</td>
<td class="border px-4 py-2">3 Phases 4 Wires, 380/400/415 V</td>
</tr>
<tr>
<td class="border px-4 py-2">Voltage Range</td>
<td class="border px-4 py-2">110–300 V @50% load; 176–276 V @100% load</td>
</tr>
<tr>
<td class="border px-4 py-2">Nominal Frequency</td>
<td class="border px-4 py-2">50/60 Hz (Auto)</td>
</tr>
<tr>
<td class="border px-4 py-2">Frequency Range</td>
<td class="border px-4 py-2">40–70 Hz</td>
</tr>
<tr>
<td class="border px-4 py-2">Power Factor</td>
<td class="border px-4 py-2">&gt;=0.99 @100% load</td>
</tr>
<tr>
<td class="border px-4 py-2">Harmonic Distortion (THDi)</td>
<td class="border px-4 py-2">&lt;4% at full linear load</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">OUTPUT</td>
</tr>
<tr>
<td class="border px-4 py-2">Voltage</td>
<td class="border px-4 py-2">3 Phases 4 Wires, 380/400/415 V ±1%</td>
</tr>
<tr>
<td class="border px-4 py-2">Frequency</td>
<td class="border px-4 py-2">50/60 Hz ±1%</td>
</tr>
<tr>
<td class="border px-4 py-2">Frequency Range (Synchronized)</td>
<td class="border px-4 py-2">46–54 Hz or 56–64 Hz</td>
</tr>
<tr>
<td class="border px-4 py-2">Harmonic Distortion</td>
<td class="border px-4 py-2">Linear load &lt;2%, Non-linear load &lt;5%</td>
</tr>
<tr>
<td class="border px-4 py-2">Overload Capacity</td>
<td class="border px-4 py-2">100–110% for 60 min, 111–125% for 10 min, 126–150% for 1 min, &gt;150% for 400 ms</td>
</tr>
<tr>
<td class="border px-4 py-2">Crest Factor</td>
<td class="border px-4 py-2">3:1</td>
</tr>
<tr>
<td class="border px-4 py-2">Wave Form</td>
<td class="border px-4 py-2">Pure sine wave</td>
</tr>
<tr>
<td class="border px-4 py-2">Transfer Time</td>
<td class="border px-4 py-2">0 ms</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">BYPASS</td>
</tr>
<tr>
<td class="border px-4 py-2">Nominal Voltage</td>
<td class="border px-4 py-2">380/400/415 V</td>
</tr>
<tr>
<td class="border px-4 py-2">Voltage Range</td>
<td class="border px-4 py-2">305–457 V</td>
</tr>
<tr>
<td class="border px-4 py-2">Frequency Range (Synchronized)</td>
<td class="border px-4 py-2">46–54 Hz or 56–64 Hz</td>
</tr>
<tr>
<td class="border px-4 py-2">Overload Capacity</td>
<td class="border px-4 py-2">&gt;130% 1 min (default); continuous operation until breaker trips (optional)</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">EFFICIENCY</td>
</tr>
<tr>
<td class="border px-4 py-2">AC Mode</td>
<td class="border px-4 py-2">96%</td>
</tr>
<tr>
<td class="border px-4 py-2">ECO Mode</td>
<td class="border px-4 py-2">99%</td>
</tr>
<tr>
<td class="border px-4 py-2">Battery Mode</td>
<td class="border px-4 py-2">95%</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">BATTERY</td>
</tr>
<tr>
<td class="border px-4 py-2">Battery Type</td>
<td class="border px-4 py-2">Depending on application</td>
</tr>
<tr>
<td class="border px-4 py-2">Battery Numbers</td>
<td class="border px-4 py-2">32–40 pcs (adjustable)</td>
</tr>
<tr>
<td class="border px-4 py-2">Max Charging Current</td>
<td class="border px-4 py-2">1–12 A (adjustable)</td>
</tr>
<tr>
<td class="border px-4 py-2">Charging Voltage</td>
<td class="border px-4 py-2">±13.65 V × N (N = 16–20)</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">INDICATORS</td>
</tr>
<tr>
<td class="border px-4 py-2">7&#8243; Touch LCD Display</td>
<td class="border px-4 py-2">UPS status, load, battery level, input/output voltage, discharge time, and fault conditions</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">SYSTEM</td>
</tr>
<tr>
<td class="border px-4 py-2">Protection</td>
<td class="border px-4 py-2">Input over/under voltage, output overload/short-circuit, inverter over-temp, battery under/over voltage</td>
</tr>
<tr>
<td class="border px-4 py-2">IP Protection</td>
<td class="border px-4 py-2">IP20</td>
</tr>
<tr>
<td class="border px-4 py-2">Parallel Mode</td>
<td class="border px-4 py-2">N+1, N+X, supports different power capacities</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">ENVIRONMENT</td>
</tr>
<tr>
<td class="border px-4 py-2">Operating Temperature</td>
<td class="border px-4 py-2">0–40°C</td>
</tr>
<tr>
<td class="border px-4 py-2">Humidity</td>
<td class="border px-4 py-2">0–95% (non-condensing)</td>
</tr>
<tr>
<td class="border px-4 py-2">Altitude</td>
<td class="border px-4 py-2">0–1500 m at full load</td>
</tr>
<tr>
<td class="border px-4 py-2">Safety Compliance</td>
<td class="border px-4 py-2">EN 62040-1:2008, EN 62040-1/EC:2009, EN 62040-1/A1:2013, Directive 2014/35/EU</td>
</tr>
<tr>
<td class="border px-4 py-2">EMC Conformance</td>
<td class="border px-4 py-2">EN 62040-2, Directive 2014/30/EU</td>
</tr>
<tr class="bg-gray-200 font-semibold">
<td class="border px-4 py-2" colspan="2">MANAGEMENT</td>
</tr>
<tr>
<td class="border px-4 py-2">Smart RS-232 / USB</td>
<td class="border px-4 py-2">Compatible with Windows, Linux, and Mac</td>
</tr>
<tr>
<td class="border px-4 py-2">SNMP</td>
<td class="border px-4 py-2">Remote management via SNMP manager or web browser</td>
</tr>
</tbody>
</table>
<p><strong>Contact us for more detail！</strong></p>
<p>&nbsp;</p>
<p><a href="https://www.upspower-supply.com/product-tag/1kva-ups/">1 KVA UPS</a>, <a href="https://www.upspower-supply.com/product-tag/3kva-ups/">3KVA UPS</a></p>
<p>The post <a href="https://www.upspower-supply.com/product/30-kva-ups-pure-sine-wave-data-center-ups/">30 kva ups, Pure sine wave data center UPS</a> appeared first on <a href="https://www.upspower-supply.com">UPS power supply</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.upspower-supply.com/product/30-kva-ups-pure-sine-wave-data-center-ups/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Industrial Medical Online UPS 30KVA 3 Three Phase 50HZ 60HZ UPS Backup Power Supply</title>
		<link>https://www.upspower-supply.com/product/industrial-medical-online-ups-30kva-3-three-phase-50hz-60hz-ups-backup-power-supply/</link>
					<comments>https://www.upspower-supply.com/product/industrial-medical-online-ups-30kva-3-three-phase-50hz-60hz-ups-backup-power-supply/#respond</comments>
		
		<dc:creator><![CDATA[Tyne Tingey]]></dc:creator>
		<pubDate>Thu, 29 May 2025 09:26:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.upspower-supply.com/?post_type=product&#038;p=1407</guid>

					<description><![CDATA[<div>The RM-U-3330 Industrial Medical Online UPS is a robust 30KVA/24KW <strong>three-phase uninterruptible power supply</strong> designed for critical applications in industrial and medical environments. Featuring a three-phase five-wire input (380/400/415V ±25%) and output (380/400/415V ±1%), it ensures stable power delivery with a 0.8 power factor and ≥92% efficiency. With a pure sine wave output (THDV &#60;2%), zero switching time, and advanced overload protection (up to 150% for 10 seconds), it guarantees reliable performance. Equipped with a 384V battery (348/360V optional), it supports seamless operation during power disruptions. The UPS includes RS232/RS485 communication (optional SNMP/JBUS/MODBUS) and operates in temperatures from -10°C to 40°C, making it ideal for demanding settings requiring uninterrupted power.</div>
<p>The post <a href="https://www.upspower-supply.com/product/industrial-medical-online-ups-30kva-3-three-phase-50hz-60hz-ups-backup-power-supply/">Industrial Medical Online UPS 30KVA 3 Three Phase 50HZ 60HZ UPS Backup Power Supply</a> appeared first on <a href="https://www.upspower-supply.com">UPS power supply</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="container mx-auto p-4">
<table class="w-full border-collapse border border-gray-300 bg-white">
<thead>
<tr class="bg-gray-200">
<th class="border border-gray-300 p-2 font-bold" colspan="2">Low Frequency Online UPS</th>
<th class="border border-gray-300 p-2">RM-U-3310</th>
<th class="border border-gray-300 p-2">RM-U-3315</th>
<th class="border border-gray-300 p-2">RM-U-3320</th>
<th class="border border-gray-300 p-2">RM-U-3330</th>
<th class="border border-gray-300 p-2">RM-U-3340</th>
<th class="border border-gray-300 p-2">RM-U-3360</th>
</tr>
</thead>
<tbody>
<tr>
<td class="border border-gray-300 p-2 font-bold" colspan="2">Rated capacity (KVA/KW)</td>
<td class="border border-gray-300 p-2 font-bold">10/8</td>
<td class="border border-gray-300 p-2 font-bold">15/12</td>
<td class="border border-gray-300 p-2 font-bold">20/16</td>
<td class="border border-gray-300 p-2 font-bold">30/24</td>
<td class="border border-gray-300 p-2 font-bold">40/32</td>
<td class="border border-gray-300 p-2 font-bold">60/48</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="5">Main Input</td>
<td class="border border-gray-300 p-2 font-bold">Phase</td>
<td class="border border-gray-300 p-2 font-bold" colspan="6">Three-phase five-wire (3L+N+PE)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold">Input Voltage (Vac)</td>
<td class="border border-gray-300 p-2 font-bold" colspan="6">380/400/415</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Voltage Range (Vac)</td>
<td class="border border-gray-300 p-2" colspan="6">±25%</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold">Frequency range (Hz)</td>
<td class="border border-gray-300 p-2 font-bold" colspan="6">45～65</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Power factor</td>
<td class="border border-gray-300 p-2" colspan="6">&gt;0.95 (with filter)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="4">Bypass Input</td>
<td class="border border-gray-300 p-2">Phase</td>
<td class="border border-gray-300 p-2" colspan="6">Three-phase five-wire (3L+N+PE)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Input Voltage (Vac)</td>
<td class="border border-gray-300 p-2" colspan="6">380/400/415</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Voltage range (Vac)</td>
<td class="border border-gray-300 p-2" colspan="6">+10%, +15%, +20% (can be set); -10%, -20%, -30% (can be set)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Input Frequency (Hz)</td>
<td class="border border-gray-300 p-2" colspan="6">50 (60) +10%</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="7">Output</td>
<td class="border border-gray-300 p-2 font-bold">Voltage (Vac)</td>
<td class="border border-gray-300 p-2 font-bold" colspan="6">380/400/415 ±1%</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold">Power factor</td>
<td class="border border-gray-300 p-2 font-bold" colspan="6">0.8</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Frequency (Hz)</td>
<td class="border border-gray-300 p-2" colspan="6">Automatically track bypass frequency</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Waveform</td>
<td class="border border-gray-300 p-2" colspan="6">Sine wave THDV less than 2% (pure linear load)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Switching time (ms)</td>
<td class="border border-gray-300 p-2" colspan="6">0 ms</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Overall efficiency</td>
<td class="border border-gray-300 p-2" colspan="3">≥91%</td>
<td class="border border-gray-300 p-2" colspan="3">≥92%</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Overload capacity</td>
<td class="border border-gray-300 p-2" colspan="6">105%~110%: 60min to bypass; 110%~125%: 10 min to bypass; 125%~150%: 1 min to bypass; &gt;150%: 10s to bypass</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold">Battery</td>
<td class="border border-gray-300 p-2">Battery voltage (Vac)</td>
<td class="border border-gray-300 p-2" colspan="3">384 (348 optional)</td>
<td class="border border-gray-300 p-2" colspan="3">384 (348/360 optional)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="5">Environment</td>
<td class="border border-gray-300 p-2">Operating temperature (°C)</td>
<td class="border border-gray-300 p-2" colspan="6">-10～40</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Storage temperature (°C)</td>
<td class="border border-gray-300 p-2" colspan="6">-25～55 (without battery)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Relative humidity</td>
<td class="border border-gray-300 p-2" colspan="6">0～95% (no frosting)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Working altitude</td>
<td class="border border-gray-300 p-2" colspan="6">&lt; 1500m, use derating according to GB/T3859.2</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Noise (dB)</td>
<td class="border border-gray-300 p-2" colspan="6">&lt;55 (1 meter from the device)</td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="3">Other features</td>
<td class="border border-gray-300 p-2">Alarm function</td>
<td class="border border-gray-300 p-2" colspan="6">Output overload, mains abnormality, UPS failure, battery undervoltage, etc.</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Protective function</td>
<td class="border border-gray-300 p-2" colspan="6">Output short circuit, overload, over temperature, battery under voltage, output over and under voltage, fan failure alarm</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Communication function</td>
<td class="border border-gray-300 p-2" colspan="6"><span class="font-bold">Standard: </span><span class="text-blue-600">RS232/RS485</span>,<br />
<span class="font-bold">Optional: </span><span class="text-blue-600">SNMP/JBUS/MODBUS/Dry Contact</span></td>
</tr>
<tr>
<td class="border border-gray-300 p-2 font-bold" rowspan="3">Mechanical features</td>
<td class="border border-gray-300 p-2">Dimensions (W*D*H mm)</td>
<td class="border border-gray-300 p-2" colspan="3">300*600*810</td>
<td class="border border-gray-300 p-2" colspan="2">400*750*1010</td>
<td class="border border-gray-300 p-2">450*810*1160</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Net weight (kg)</td>
<td class="border border-gray-300 p-2">84</td>
<td class="border border-gray-300 p-2">106</td>
<td class="border border-gray-300 p-2">113</td>
<td class="border border-gray-300 p-2">177</td>
<td class="border border-gray-300 p-2">195</td>
<td class="border border-gray-300 p-2">270</td>
</tr>
<tr>
<td class="border border-gray-300 p-2">Executive standard</td>
<td class="border border-gray-300 p-2" colspan="6">YD/T1095-2017</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.upspower-supply.com/product/industrial-medical-online-ups-30kva-3-three-phase-50hz-60hz-ups-backup-power-supply/">Industrial Medical Online UPS 30KVA 3 Three Phase 50HZ 60HZ UPS Backup Power Supply</a> appeared first on <a href="https://www.upspower-supply.com">UPS power supply</a>.</p>